LT25/50/100 series gas pressure regulator

     
       
 

2 Introduction:
LT25/50/100 series gas pressure regulatorThe LT25/50/100 series voltage regulator for direct acting pressure regulator. Applicable to high, low voltage distribution system, in. Equipped with super high and low pressure safety protection device. Has the characteristics of simple structure, convenient operation, convenient maintenance, on-line fast response etc..

2 Technical parameters:
The maximum inlet pressure /P1max:6bar
Inlet pressure range /δ P1:0.05-5bar
Outlet pressure range / standardδ P2:15 ~ 500mbar
/AP high-voltage Delta P2:500 ~ 1000mbar
/APA ultra highδ P2:1000 ~ 3000mbar
Overpressure cutting set pressure Who:22.5~1500mbar
Low cut set pressure Whu:12.8~700mbar
Accuracy of ± 8% /AC:
Closing pressure: /SG≤ 20%
The cutting accuracy of ± 5% /AQ:
Response time: /ta≤ 1sec
The maximum flow rate ( NG ) /Qmax : see the flow table
Working temperature: -20 ~ +60 ℃




 
       

LT25/50/100 flow control table

       
LT25/50/100 flow control table
       
 