RTJ-※/※N Series Indirect-action Mode Pressure Regulator for Gas |
|
|
|
|
|
2 Application
RTJ-※/※N Series Indirect-action mode pressure regulator for gas is used for high middle-pressure, middle middle-pressure first class gas transmission and distribution system, It can be used as district regulators or for industry and commerce users as well as direct-fired equipments. It is applicable for natural gas, artificial coal gas and liquefied petroleum gas(LPG).
It accords with the standard CJ274-2008 “City Gas Pressure Regulators”.
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
2 Main Technical Parameters
Inlet Pressure Rank(P1): ≤1.6MPa
Outlet Pressure Rank(P2): 0.02~0.8MPa
Pressure Precision Grade: AC5
Shut Off Pressure Grade: SG10
Working Temperature(t): -20~60℃
Caliber: DN50, DN80, DN100, DN150
Flange Pressure Class: PN1.6MPa
|
2 Features
Accurate adjustment of outlet, set simply
The whole balanced spool structure, high-precision voltage regulator
Fast response, large flow capacity
Valve position display
Modular structure, easy maintenance on line
|
|
|
|
|
|
|
Dimension |
Code
Model |
A |
B |
L |
H1 |
H |
Inlet & Outlet Flange |
RTJ-50/※N |
330 |
377 |
254 |
181 |
395 |
DN50 |
RTJ-80/※N |
420 |
464 |
298 |
282 |
498 |
DN80 |
RTJ-100/※N |
420 |
464 |
352 |
302 |
538 |
DN100 |
RTJ-150/※N |
420 |
464 |
451 |
322 |
578 |
DN150 |
|
RTJ-50/※N Flow Meter (Cross-reference for natural gas media) |
Outlet pressure(KPa) |
Inlet Pressure(MPa) |
0.1 |
0.2 |
0.4 |
0.6 |
0.8 |
1.3 |
1.5 |
2.0 |
2.3 |
0.03 |
290 |
580 |
1123 |
1650 |
2165 |
2887 |
3561 |
5020 |
6300 |
0.08 |
190 |
580 |
1123 |
1650 |
2165 |
2887 |
3561 |
5020 |
6300 |
0.12 |
- |
500 |
1123 |
1600 |
2105 |
2752 |
3420 |
5020 |
6000 |
0.2 |
- |
- |
1123 |
1600 |
2105 |
2752 |
3420 |
4987 |
6000 |
0.3 |
- |
- |
1058 |
1543 |
2000 |
2651 |
3264 |
4865 |
6000 |
0.4 |
- |
- |
- |
1543 |
2000 |
2651 |
3264 |
4865 |
6000 |
|
|
RTJ-80/※N Flow Meter (Cross-reference for natural gas media) |
Outlet pressure(KPa) |
Inlet Pressure(MPa) |
0.1 |
0.2 |
0.4 |
0.6 |
0.8 |
1.3 |
1.5 |
2.0 |
2.3 |
0.03 |
550 |
1280 |
2100 |
3100 |
4000 |
6500 |
7895 |
10550 |
12000 |
0.08 |
550 |
1280 |
2080 |
3100 |
4000 |
6500 |
7895 |
10550 |
12000 |
0.12 |
- |
1280 |
2080 |
3000 |
3850 |
6000 |
7865 |
10060 |
11210 |
0.2 |
- |
- |
1950 |
3000 |
3850 |
6000 |
7865 |
10060 |
11210 |
0.3 |
- |
- |
1500 |
2800 |
3742 |
5400 |
7520 |
10060 |
10750 |
0.4 |
- |
- |
- |
2800 |
3742 |
5400 |
7520 |
10060 |
10750 |
|
RTJ-100/※N Flow Meter (Cross-reference for natural gas media) |
Outlet pressure(KPa) |
Inlet Pressure(MPa) |
0.1 |
0.2 |
0.4 |
0.6 |
0.8 |
1.3 |
1.5 |
2.0 |
2.3 |
0.03 |
625 |
1250 |
2700 |
3750 |
5400 |
7500 |
8900 |
12500 |
14375 |
0.08 |
625 |
1250 |
2700 |
3750 |
5400 |
7500 |
8900 |
12500 |
14375 |
0.12 |
- |
1000 |
2500 |
3700 |
5000 |
7200 |
8600 |
12000 |
14200 |
0.2 |
- |
- |
2500 |
3700 |
5000 |
7200 |
8600 |
12000 |
14200 |
0.3 |
- |
- |
2500 |
3650 |
4520 |
6854 |
8250 |
11000 |
13100 |
0.4 |
- |
- |
- |
3650 |
4520 |
6854 |
7250 |
11000 |
13100 |
|
RTJ-150/※N Flow Meter (Cross-reference for natural gas media) |
Outlet pressure(KPa) |
Inlet Pressure(MPa) |
0.1 |
0.2 |
0.4 |
0.6 |
0.8 |
1.3 |
1.5 |
2.0 |
2.3 |
0.03 |
921 |
1600 |
3574 |
6005 |
8900 |
15800 |
26020 |
34000 |
40000 |
0.08 |
900 |
1600 |
3123 |
6005 |
8600 |
14210 |
26020 |
34000 |
40000 |
0.12 |
- |
1320 |
3021 |
5840 |
8600 |
18650 |
25000 |
33000 |
38000 |
0.2 |
- |
- |
2850 |
5840 |
8250 |
15361 |
25000 |
33000 |
38000 |
0.3 |
- |
- |
2400 |
5800 |
7250 |
12358 |
23000 |
32000 |
35000 |
0.4 |
- |
- |
- |
5800 |
7000 |
10745 |
23000 |
32000 |
35000 |
|
|
|
|
|
|
2 (PS: The figures showed in the chart are the flows when the Natural gas relative density reached 0.6 under the standard statement. Other gas flow should be multiplied by their conversion coefficient: Propane: 0.63, Butane: 0.55, Gas: 0.78 Nitrogen: 0.79)
|
|
|
|
|
|
|
|