Building gas regulator box |
 |
 |
 |
| |
|
|
|
| |
2 Brief introduction:
YWH building gas regulator box, widely applied to housing districts and school canteens, is an equipment for the gas pressure regulator which is low pressure and small compacility. It can be used to control and remain the pressure for the gas, liquefied natural gas, coal gas and noncorrosivegas. |
2 Features:
1銆丠igh precision in pressure regulating and remaining, quick reaction, complete functions.
2銆丳rotection of cutting off high and low pressure, desorption inside.
3銆丗ast installation, easy maintenance, good safety.
4銆乀he box is rich looking and beautiful,which is adhere to the requirements of the park and garden construction in the housing district. |
|
| |
|
|
|
|
| The main technical parameters 锛 |
Regulator box(station)鈥檚 mode |
YWH-10A |
YWH-25A |
YWH-50A |
YWH-70A |
YWH-100A |
Main regulator |
B10 |
B25 |
B50 |
B70 |
B100 |
RTZ-FQ |
RTZ-FQ |
1883B2 |
1883B2 |
1883 |
Entrance pressure鈥檚 range(Mpa) |
0.05-0.5 |
0.05-0.5 |
0.05-0.5 |
0.05-0.5 |
0.05-0.5 |
Exit pressure鈥檚 range (Kpa) |
2.4 |
2.4 |
2.4 |
2.4 |
2.4 |
Maximum Flow(NG Nm3/h) |
10 |
25 |
50 |
70 |
100 |
Weight of the regulator box |
12 |
15 |
18 |
20 |
20 |
Regulating precision(未P2) |
鈮ぢ5% |
Closing precision |
鈮10% |
Working tempreture |
-20鈩冿綖+60鈩 |
Gases applied |
City gas,LPG, Mixed gas, NG |
|
| |
Direct combustion pressure regulator box |
| |
|
|
|
| |
2 Brief introduction:
In china,we use direct combustion equipments. For instance, gas fired boiler, gas air conditioner and gas burner are all used with low pressure of 50-100mbar. And those are using low pressure of 50-150mbar. Knowing this kind of equipment鈥檚 feature, our company has already developed a series of high quality direct combustion pressure regulating boxes. These products are designed for industrial gas, the flow rate shocks, open and shut promptly and uninterrupted gas supply. It owns many functions such as filter, voltage regulation and computation. It also can reflect rapidly, steady outlet pressure and highly closed precision under the condition of the unpredictable change for the range of flow to meet the needs of industrial and civilian use. |
|
 |
| |
|
|
|
|
| |
|
|
|
| |
 |
2 Features:
- The major components of regulator are the major regulator, limiting pressure closing system, flow meter and meter control. Those are premium brands to guarantee its high quality, high degree of accuracy and high reliability
- The pressure regulating box owns a high accuracy degree of filter (5渭m). Users can change the filter timely for differential manometer can reflect how dirty the filter element is.
- The regulator is furnished with limiting pressure closing system. When loses control, it can disconnect air supply automatically to ensure the steady of the manometer.
- We can regulate the manometer both artificial and automatic method to make sure the instantly air supply
- It experienced strict pressure-tight and gas-tight test to ensure the system of no leakage.
|
|
| |
|
|
|
|
| |
| The main technical parameters锛 |
Regulator鈥橫ode |
YWH-200A/B |
YWH-300A/B |
YWH-600A/B |
YWH-1000A/B |
YWH-2000A/B |
YWH-3000A/B |
Main regulator |
A109 |
A149 |
MBN/40 |
MBN/50 |
MBN/80-BP |
MBN/100-BP |
RTZ-SL |
133L |
133L |
133L |
133L |
RTJ-N |
Entrance pressure鈥檚 range(Mpa) |
0.1-0.5 |
0.1-0.5 |
0.1-0.5 |
0.1-0.5 |
0.1-0.5 |
0.1-0.5 |
Exit pressure鈥檚 range(Kpa) |
2.4 |
2.4 |
2.4 |
2.4 |
2.4 |
2.4 |
Maximum flow(NG Nm3/h) |
鈮200 |
300-400 |
500-800 |
900-1000 |
2000-2800 |
300-4000 |
Entrance caliber |
DN50
PN1.6 |
DN50
PN1.6 |
DN65
PN1.6 |
DN80
PN1.6 |
DN125
PN1.6 |
DN150
PN1.6 |
Exit caliber |
DN50
PN1.6 |
DN65
PN1.6 |
DN100
PN1.6 |
DN125
PN1.6 |
DN200
PN1.6 |
DN200
PN1.6 |
Entrance/Exit central distance
(mm)d |
A |
850 |
810 |
900 |
930 |
2070 |
2050 |
B |
850 |
810 |
900 |
930 |
2070 |
2050 |
Size of the box
(mm)
a脳b脳c |
A |
1300脳1000脳1130 |
1300脳1000脳1280 |
1500脳1200脳1850 |
1550脳1200脳1900 |
2700脳1460脳2200 |
2730脳1650脳2310 |
B |
1300脳550脳1130 |
1300脳550脳1180 |
1450脳750脳1600 |
1650脳850脳1600 |
2700脳960脳1800 |
2730脳1060脳1800 |
Regulating precision(未P2) |
鈮ぢ5% |
Closing precision |
鈮10% |
Working temperature |
-20鈩 - +60鈩 |
Applied medium |
City gas銆丩PG銆丮ixed gas銆丯G and Noncorrosivegas. |
|
| |
Divide regulator box |
| |
|
|
|
| |
聽2 Brife introduction:
YWH gas regulator box is an equipment to combine filtration, regulator, computation and safety control into one. It has a lot of advantages, such as samll volume, easy installation, good coordination in system and good safety. It is widely applied to offer gas for housing district, hotel, factory and school.
2 Features:
- The major components of regulator are the major regulator, limiting pressure closing system, flow meter and meter control. Those are premium brands to guarantee its high quality, high degree of accuracy and high reliability.
- The pressure regulating box owns a high accuracy degree of filter (5渭m). Users can change the filter timely for differential manometer can reflect how dirty the filter element is.
- The regulator is furnished with limiting pressure closing system. When loses control, it can disconnect air supply automatically to ensure the steady of the manometer.
- We can regulate the manometer both artificial and automatic method to make sure the instantly air supply.
- It experienced strict pressure-tight and gas-tight test to ensure the system of no leakage.
|
 |
|
| |
 |
|
| |
|
|
|
|
| |
| The main technical parameters 锛 |
Regulator鈥檚 mode |
YWH-200A/B |
YWH-300A/B |
YWH-600A/B |
YWH-1000A/B |
YWH-2000A/B |
YWH-3000A/B |
Main regulator |
A109 |
A149 |
MBN/40 |
MBN/50 |
MBN/80-BP |
MBN/100-BP |
1883 |
1883 |
299HS |
299HS |
REGAL3 |
REGAL3 |
Entrance pressure鈥檚 range(Mpa) |
0.1-0.5 |
0.1-0.5 |
0.1-0.5 |
0.1-0.5 |
0.1-0.5 |
0.1-0.5 |
Exit pressure鈥檚 range(Kpa) |
2.4 |
2.4 |
2.4 |
2.4 |
2.4 |
2.4 |
Maximum flow(NG Nm3/h) |
鈮200 |
300-400 |
500-800 |
900-1000 |
2000-2800 |
300-4000 |
Entrance caliber |
DN50
PN1.6 |
DN50
PN1.6 |
DN65
PN1.6 |
DN80
PN1.6 |
DN125
PN1.6 |
DN150
PN1.6 |
Exit caliber |
DN50
PN1.6 |
DN65
PN1.6 |
DN100
PN1.6 |
DN125
PN1.6 |
DN200
PN1.6 |
DN200
PN1.6 |
Entrance/Exit central distance
(mm)d |
A |
850 |
810 |
900 |
930 |
2070 |
2050 |
B |
850 |
810 |
900 |
930 |
2070 |
2050 |
Size of the box
(mm)
a脳b脳c |
A |
1300脳1000脳1130 |
1300脳1000脳1280 |
1500脳1200脳1850 |
1550脳1200脳1900 |
2700脳1460脳2200 |
2730脳1650脳2310 |
B |
1300脳550脳1130 |
1300脳550脳1180 |
1450脳750脳1600 |
1650脳850脳1600 |
2700脳960脳1800 |
2730脳1060脳1800 |
Regulating precision (未P2) |
鈮ぢ5% |
Closing precision |
鈮10% |
Working Tempreture |
-20鈩 - +60鈩 |
Applied medium |
City gas, LNG, mixed gas, NG |
|
| |
| 杩斿洖 |
| |