2 OPERATING CONDITIONS :
Inlet gas temperature: Ambient temperature
Suction pressure: 0.35~0.8MPa(g)
Discharge pressure: 25MPa (g)
Discharge temperature: ≤Ambient temperature
Capacity: 875~1650Nm3/h (A 250KW may be equipped according to working conditions of users, both motors are applicable.)
Low vibration, low noise, convenient for operation and maintenance, safe and reliable, highly efficient and energy saving.
|
2 Features :
Heavy load frame, reasonable internal rib configuration, and integral crosshead guide.
All driving parts are forged with high quality alloy steel.
The unit is air cooled, skid-mounted enclosure structure, easy to install.
With sound insulation enclosure of special design the external noise is lower than 76dBA.
PLC control system monitors the status, temperature and pressure, automatic start-up and shutdown of the unit is realized
The unit is equipped with full safety devices. All electrical components are in conformity to the Ex-proof requirements of natural gas environment.
The skid-mounted enclosure is equipped with roof rail, pulley and Ex-proof lamp inside.
Gas valve and packing of international brands assure reliable quality and long service life.
|
|